lead wire

B, C, D - Military Wire
MIL-W-16878/1 Type B (105C) (600 Volts)

Wire Gauge (AWG) NO. Conductor Stranding Insulation Thickness Wire Thickness Approximate Lbs.
per 1000ft
30 7/38 Tinned .010 .031 .085
28 7/36Tinned .010 .035 1.08
26 7/34 Tinned .010 .039 1.46
24 7/32 Tinned .010 .044 2.18
24 19/36 Tinned .010 .044 2.18
22 7/30 Tinned .010 .051 2.99
22 19/34 Tinned .010 .051 3.19
20 7/28 Tinned .010 .058 4.43
20 19/32 Tinned .010 .058 4.72
18 7/26 Tinned .010 .070 6.68
18 19/30 Tinned .010 .070 7.03
16 19/29 Tinned .010 .077 8.89
14 19/27 Tinned .010 .090 13.54


MIL-W-16878/2 Type C (105C) (1000 Volts)

Wire Gauge (AWG) NO. Conductor Stranding Insulation Thickness Wire Thickness Approximate Lbs.
per 1000ft
28 7/36 Tinned .017 .047 1.60
26 7/34Tinned .017 .051 2.00
24 7/32 Tinned .017 .058 2.77
24 19/36 Tinned .017 .058 2.88
22 7/30 Tinned .017 .063 3.65
22 19/34 Tinned .017 .063 3.84
20 7/28 Tinned .017 .072 5.17
20 19/32 Tinned .017 .072 5.17
18 7/26 Tinned .017 .082 7.54
18 19/30 Tinned .017 .082 8.04
16 19/29 Tinned .017 .092 9.86
14 19/27 Tinned .017 .105 14.65
12 19/25 Tinned .017 .124 22.51


MIL-W-16878/3 Type D (105C) (3000 Volts)

Wire Gauge (AWG) NO. Conductor Stranding Insulation Thickness Wire Thickness Approximate Lbs.
per 1000ft
24 7/32 Tinned .031 .086 4.85
22 7/30 Tinned .031 .093 5.91
20 7/28 Tinned .031 .100 7.63
18 7/26 Tinned .031 .110 10.29
16 19/29 Tinned .031 .120 12.87
14 19/27 Tinned .031 .134 18.05
12 19/25 Tinned .037 .160 27.27
10 37/26 Tinned .037 .182 39.8
8 133/29 Tinned .037 .245 68.7
6 133/27 Tinned .037 .295 102.7



MIL-W-76D Type MW
Medium Wall PVC MIL-Spec Wire (1000 V) (-40C to 80C)

Wire Gauge (AWG) Conductor Stranding Insulation Thickness Wire Thickness Approximate Lbs.
per 1000ft
24 7/32 Tinned 0.016 0.057 2.63
22 7/30 Tinned 0.016 0.062 3.34
20 10/30 Tinned 0.016 0.070 4.69
18 16/30 Tinned 0.016 0.079 6.82
16 26/30 Tinned 0.016 0.091 10.30
14 41/30 Tinned 0.016 0.110 15.53
12 65/30 Tinned 0.016 0.131 23.90


● Used for wiring of electronic equipment.
● MIL-W-76D superseded MIL-W-76B in Sept. 1992.
● We can stripe and print for your needs.

1061/MIL-W-16878/1/Type B
Semi-rigid PVC (80C) (300 Volts) (UL and CSA)

Wire Gauge (AWG) Conductor Stranding Insulation Thickness Wire Thickness Approximate Lbs.
per 1000ft
26 7/34 Tinned .009 .038 1.5
24 7/32 Tinned .009 .045 2.0
22 7/30 Tinned .009 .051 3.0
20 10/30 Tinned .009 .058 4.0
18 16/30 Tinned .009 .067 6.5
16 26/30 Tinned .009 .078 8.5


● Used in internal wiring of appliances and electronic equipment.
● Overcoat, topcoat, and prebond stranding available.
● We can stripe and print for your needs.

1007/1569/Mil-W-16878/2 Type C
PVC Hookup Wire (VW-1)
UL 1007 80C/300V
CSA TR64 90C/300V
UL1569 105C/300V
CSA AWM 1 A/B 105C/300V FT 1
Mil-W-16878/2 Type C 105C/1000V

Wire Gauge (AWG) Conductor Stranding Insulation Thickness Wire Thickness Approximate Lbs.
per 1000ft
26 7/34 Tinned .015 .051 2
24 7/32 Tinned .015 .057 2.5
24 19/36 Tinned .015 .057 2.5
24 Solid Tinned .015 .052 2.5
24 7/32 Topcoat .015 .057 2.5
22 7/30 Tinned .015 .062 3.3
22 19/34 Tinned .015 .062 3.7
22 Solid Tinned .015 .062 3
22 7/30 Topcoat .015 .062 4
20 10/30 Tinned .015 .070 4.7
20 19/32 Tinned .015 .073 5
20 Solid Tinned .015 .067 4.7
20 10/30 Topcoat .015 .067 4.7
18 16/30 Tinned .015 .079 7
18 19/.0092 Tinned .015 .079 7
18 Solid Tinned .015 .073 6.5
18 16/30 Topcoat .015 .079 7
16 26/30 Tinned .015 .095 10.5
16 Solid Tinned .015 .091 10
16 26/30 Topcoat .015 .095 10
14 41/30 Tinned .015 .110 16
12 65/30 Tinned .015 .131 24
10 105/30 Tinned .015 .145 36


● Used in internal wiring of appliances and electronic equipment.
● Overcoat, topcoat, and prebond stranding available.
● We can stripe and print for your needs.

1015/1011/1028/1032/1230/1231/1335/1344/MTW/TEW (Bare Copper)
PVC Machine Tool Wire/Thermoplastic Equipment Wire
(90C MTW) (UL and CSA 105C) (VW-1 and Moisture Resistant) (600 Volts) (1032 - 1000 Volts)
Marine approvals for 16-8 AWG meets UL Standard 1426 BC-5W2, SAE J378, USCG, ABYC, and NMMA

Wire Gauge (AWG) Conductor Stranding Insulation Thickness Wire Thickness Approximate Lbs.
per 1000ft
22 7/30 Bare .03125 .091 5
22 Solid Bare .03125 .088 5
20 10/30 Bare .03125 .099 7
20 Solid Bare .03125 .096 7
18 16/30 Bare .03125 .106 9
18 Solid Bare .03125 .102 9
16 26/30 Bare .03125 .117 13
16 Solid Bare .03125 .112 13
14 13/.0147 Bare .03125 .132 18
14 41/30 Bare .03125 .132 18
14 Solid Bare .03125 .124 18
12 19/.0185 Bare .03125 .151 27
12 65/30 Bare .03125 .151 27
12 Solid Bare .03125 .145 27
10 19/.0234 Bare .03125 .175 40
10 105/30 Bare .03125 .175 41
10 Solid Bare .03125 .165 41
8 19/.0295 Bare .047 .242 68
8 133/29 Bare .048 .252 67


● Used in internal wiring of appliances, control cabinets, and for machine tools.
● Overcoat, topcoat, and prebond stranding available.
● We can stripe and print for your needs.

1232/1283/1284/1338/1339/1340/1346/10269/MTW/TEW (Bare Copper)
PVC Machine Tool Wire/Thermoplastic Equipment Wire/Thermoplastic Equipment Wire (TEW)
Extra Flexible and Standard Large MTW/TEW
(90C MTW) (UL and CSA 105C) (VW-1 and Moisture Resistant) (600 Volts)

Wire Gauge (AWG) Conductor Stranding Insulation Thickness Wire Thickness Approximate Lbs.
per 1000ft
6 19/.0372 Bare .060 .306 110
6 266/30 Bare .060 .355 118
4 19/.0469 Bare .060 .355 166
4 420/30 Bare .060 .367 164
2 19/.0591 Bare .060 .415 250
2 665/30 Bare .060 .432 251
1 833/30 Bare .080 .521 332
1/0 1064/30 Bare .080 .561 402
2/0 1330/30 Bare .080 .616 492
3/0 1672/30 Bare .080 .666 612
4/0 2109/30 Bare .080 .726 758
250 MCM 2451/30 Bare .095 .835 956
350 MCM 3458/30 Bare .100 1.045 1350
400 MCM 4123/30 Bare .98 1.16 1475
500 MCM 5054/30 Bare .130 1.275 1968
750 MCM 7581/30 Bare .115 1.38 2853


● Used in internal wiring of appliances, control cabinets, and for machine tools.
● #6 - 4/0 flexible MTW/TEW includes THHW, boat cable BC-5W2, SAE J1127 Type SGT, UL 10269 - 1000 Volts
● 1/0 -750 MCM is Cable Tray rated.
● We can stripe and print for your needs.

1015/1011/1028/1032/1230/1231/1335/1344/MTW/TEW (Tinned Copper)
PVC Machine Tool Wire/Thermoplastic Equipment Wire/Thermoplastic Equipment Wire (TEW)
(90C MTW) (UL and CSA 105C) (VW-1 and Moisture Resistant) (600 Volts) (1032 - 1000 Volts)
Marine approvals for 16-8 AWG meets UL Standard 1426 BC-5W2, SAE, J378, USCG, ABYC, and NMMA

Wire Gauge (AWG) Conductor Stranding Insulation Thickness Wire Thickness Approximate Lbs.
per 1000ft
26 7/34 Tinned .03125 .081 4
24 7/32Tinned .03125 .087 4.7
22 7/30 Tinned .03125 .091 5
20 10/30 Tinned .03125 .099 7
20 10/30 Topcoat .03125 .99 7
18 Solid Tinned .03125 .102 9
18 16/30 Tinned .03125 .106 9
18 16/30 Topcoat .03125 .106 10
16 26/30 Tinned .03125 .117 13
16 26/30 Topcoat .03125 .117 13
14 41/30 Tinned .03125 .132 18
12 65/30 Tinned .03125 .151 27
10 105/30 Tinned .03125 .175 41
8 133/29 Tinned .048 .252 68


● Used in appliances, controls, ballasts, electronic circuits, hookups, motors, switchboards, and transformers.
● 24 and 26 AWG tinned is not MTW rated and not marine approved
● We can stripe and print for your needs.

1015/1011/1028/1032/1230/1231/1335/1344/MTW/TEW (Tinned Copper)
PVC Machine Tool Wire/Thermoplastic Equipment Wire/Thermoplastic Equipment Wire (TEW)
Extra Flexible and Standard Large MTW/TEW
(90C MTW) (UL and CSA 105C) (VW-1 and Moisture Resistant) (600 Volts)

Wire Gauge (AWG) Conductor Stranding Insulation Thickness Wire Thickness Approximate Lbs.
per 1000ft
6 266/30 Tinned .060 .322 114
4 420/30 Tinned .060 .372 167
2 665/30 Tinned .060 .437 252
1 833/30 Tinned .080 .521 332
1/0 1064/30 Tinned .080 .561 402
2/0 1330/30 Tinned .080 .616 495
3/0 1672/30 Tinned .080 .666 612
4/0 2109/30 Tinned .080 .726 758
250 MCM 2499/30 Tinned .100 .887 978
350 MCM 3458/30 Tinned .100 1.045 1350
400 MCM 4123/30 Tinned .098 1.16 1475
500 MCM 5054/30 Tinned .130 1.275 1968
750 MCM 7581/30 Tinned .115 1.38 2853


● Used in internal wiring of appliances, control cabinets, and for machine tools.
● #6 - 4/0 flexible MTW/TEW includes THHW, boat cable BC-5W2, SAE J1127 Type SGT, UL 10269 - 1000 Volts
● 1/0 -750 MCM is Cable Tray rated.
● We can stripe and print for your needs.

1275/1056, 1276/1060
PVC Heavy Wall Lead, Hookup Wire and Refrigeration Wire
(105C) VW-1 and Moisture Resistant) (600 Volts) (UL and CSA)

Wire Gauge (AWG) Conductor Stranding Insulation Thickness Wire Thickness Approximate Lbs.
per 1000ft
18 16/30 Bare .063 .174 18.4
16 26/30 Bare .063 .186 23
14 41/30 Bare .078 .234 36.3
12 65/30 Bare .078 .252 46.2
10 105/30 Bare .078 .280 63.3


● Used in appliances, equipment, ballasts, controls, electronic circuits, hookups, motors, panels, switchboards, transformers, refrigeration equipment and room cooler units.
● We can stripe and print for your needs.

1422/1423 Kynar Insulated Wire Wrap
105C, No Voltage Rating

Wire Gauge (AWG) Conductor Stranding Insulation Thickness Wire Thickness Approximate Lbs.
per 1000ft
30 Solid SPC .004 .0195 .47
28 Solid SPC .005 .0240 .73
26 Solid SPC .006 .0270 1.05


● Used as appliance wiring material suitable for back panel areas of electronic computers and business machines here not subject to movement or mechanical damage.
● SPC is silver plated copper.

1659
Polytetra Fluoroethylene (PTFE) (600 Volts) (250C)

Wire Gauge (AWG) Conductor Stranding Insulation Thickness Wire Thickness Approximate Lbs.
per 1000ft
22 19/.0063 NPC .020 .070 5.70
20 19/.0080 NPC .020 .078 7.65
18 19/.0100 NPC .020 .087 10.5
16 19/.0117 NPC .020 .096 13.4
14 19/.0147 NPC .020 .109 18.8
12 19/.0185 NPC .020 .128 27.6
10 37/.0157 NPC .020 .154 39.00


● Used in internal wiring of appliances and electronic equipment.
● PTFE lead wires have a low coefficient of friction. Also resists hot soldering irons, is self-extinguishing, non-flammable, chemical resistant, and suitable for immersion in gasoline or gas vapor.
● Conductor is nickel plated copper.

10086/CSA, Class1, Group A/B
Tefzel-Extruded ETFE 200C/600V

Wire Gauge (AWG) Conductor Stranding Insulation Thickness Wire Thickness Approximate Lbs.
per 1000ft
20 7/28BC .010 .058 5
18 7/.0152BC .010 .066 6
16 7/.0192BC .010 .078 10
14 7/.0242BC .010 .092 15
12 19/.0185BC .015 .119 23


● Used in internal wiring of electrical equipment and UL classified appliance wiring service up to 200C.
● Conductor also available in tin-plated copper or silver-plated copper.
● We can stripe and print for your needs.

3173/3195/3196
Chemically Cross-linked Polyethylene (XLPE) (600 Volts) (UL and CSA) (125C)

Wire Gauge (AWG) Conductor Stranding Insulation Thickness Wire Thickness Approximate Lbs.
per 1000ft
22 7/30 Tinned .030 .090 5
20 10/30 Tinned .030 .103 7.5
18 16/30 Tinned .030 .110 10
16 26/30 Tinned .030 .121 13
14 41/30 Tinned .030 .138 19
12 65/30 Tinned .030 .157 28
10 105/30 Tinned .030 .187 43
8 133/29 Tinned .045 .261 69
6 133/27 Tinned .060 .338 115
4 133/25 Tinned .060 .392 174


● Used for appliances, coil leads, switchboard panels, transformers, motor leads and power operated dispensing units.
● 22 AWG, 20 AWG, 18 AWG and 16 AWG are also printed with "SWITCHBOARD WIRE" for SIS applications.
● 14 AWG through 4 AWG are also printed with "SIS" for non VW-1 SIS applications.
● We can stripe and print for your needs.

3321/3505
Chemically Cross-linked Polyethylene Insulation (XLP) (150C) (600 Volts) (CSA FT 1)

Wire Gauge (AWG) Conductor Stranding Insulation Thickness Wire Thickness Approximate Lbs.
per 1000ft
20 10/30 Tinned .030 .103 7
8 16/30 Tinned .030 .110 10
16 26/30 Tinned .030 .121 13
14 41/30 Tinned .030 .138 19
12 65/30 Tinned .030 .157 27
10 105/30 Tinned .030 187 42
8 133/29 Tinned .045 .257 66
6 133/27 Tinned .060 .335 113


● Used in appliances, transformers, electrical and gas heating, motors, ballast, lighting, hairdressing and cooking equipment.
● We can stripe and print for your needs.

E/1213/1371
Type E Teflon (-60C to 200C) (600 Volts)
UL1213 (-60C to 105C) (Voltage - na)

Wire Gauge (AWG) Conductor Stranding Insulation Thickness Wire Thickness Approximate Lbs.
per 1000ft
30 Solid SPC .010 .030 0.90
30 7/38 SPC .010 .032 1.00
28 Solid SPC .010 .033 1.12
28 7/36 SPC .010 .035 1.23
28 19/40 SPC .010 .035 1.25
26 Solid SPC .010 .036 1.55
26 7/34 SPC .010 .039 1.74
26 19/38 SPC .010 .039 1.78
24 Solid SPC .010 .041 2.12
24 7/32 SPC .010 .044 2.35
24 19/36 SPC .010 .045 2.46
22 Solid SPC .010 .045 2.92
22 7/30 SPC .010 .048 3.33
22 19/34 SPC .010 .051 3.43
20 Solid SPC .010 .054 4.19
20 7/28 SPC .010 .057 4.98
20 19/32 SPC .010 .058 5.10
18 7/26 SPC .010 .069 7.70
18 19/30 SPC .010 .069 7.75
16 19/29 SPC .010 .080 10.00
14 1927 SPC .013 .095 16.00
12 19/25 SPC .013 .114 24.00
10 37/26 SPC .013 .134 34.00


● Used in internal wiring of electrical equipment where exposed to mechanical abuse for high temperature applications in computers, business machines, and meters.
● SPC is silver plated copper conductor.
● UL requires slightly different strand size on 16AWG and larger.
● No imprint required for Military or UL.  UL requires UL tags.
● 18AWG and smaller is UL tagged.
● 16AWG and larger is MIL-SPEC only.  UL/CSA available on special order.
● CSA material rated 150C, 150 volts, and type AWM.
● Meets NEMA HP3 and is made to old MIL-W-1878 specification.

EE/1180
Type EE Teflon (-60C to 200C) (600 Volts)
UL1180 (-60C to 200C) (300 Volts)

Wire Gauge (AWG) Conductor Stranding Insulation Thickness Wire Thickness Approximate Lbs.
per 1000ft
28 7/36 SPC .015 .045 1.90
26 Solid SPC .015 .047 2.18
26 7/34 SPC .015 .049 2.40
26 19/38 SPC .015 .049 2.48
24 7/32 SPC .015 .054 3.25
24 19/36 SPC .015 .054 3.70
22 7/30 SPC .015 .060 4.19
22 19/34 SPC .015 .061 4.32
20 7/28 SPC .015 .068 5.85
20 19/32 SPC .015 .069 6.10
18 7/26 SPC .015 .079 8.35
18 19/30 SPC .015 .080 8.52
16 19/29 SPC .015 .090 11.00
14 19/27 SPC .017 .106 17.00
12 19/25 SPC .017 .125 25.00
10 37/26 SPC .017 .145 37.00
8 133/29 SPC .020 .210 64.00
6 133/27 SPC .030 .263 122.00


● Used in internal wiring of electrical equipment where exposed to mechanical abuse for high temperature applications in computers, business machines, and meters.
● SPC is silver plated copper conductor.
● UL requires slightly different strand size on 16AWG and larger.
● No imprint required for Military or UL.  UL requires UL tags.
● 18AWG and smaller is UL tagged.
● 16AWG and larger is MIL-SPEC only.  UL/CSA available on special order.
● CSA material rated 150C, 150 volts, and type AWM.
● Meets NEMA HP3 and is made to old MIL-W-1878 specification.

EPDM/3340/3374
Ethylene-propylene-diene Monomor Appliance and Motor Lead Wire
(125C/Flexing, 150C/Non-Flexing) (600 Volts)

Wire Gauge (AWG) Conductor Stranding Insulation Thickness Wire Thickness Approximate Lbs.
per 1000ft
18 16/30 Tinned .045 .140 5
16 26/30 Tinned .045 .153 8
14 41/30 Tinned .045 .168 13
12 65/30 Tinned .045 .187 20
10 105/30 Tinned .045 .216 32
8 84/27 Tinned .060 .297 52
6 133/27 Tinned .060 .345 82
4 133/25 Tinned .060 .392 133
2 665/30 Tinned .060 .465 210
1 833/30 Tinned .080 .520 260
1/0 1064/30 Tinned .080 .550 335
2/0 1330/30 Tinned .080 .620 420
3/0 1672/30 Tinned .080 .694 518
4/0 2109/30 Tinned .080 .720 665


● Used as appliance wire and as lead wire for motors, transformers, coils, ballasts or solenoids.

EPDM/3499 - High Voltage
Ethylene-propylene-diene Monomor High Voltage Appliance and Motor Lead Wire
(150C) (7500 Volts)

Wire Gauge (AWG) Conductor Stranding Insulation Thickness Wire Thickness Approximate Lbs.
per 1000ft
8 84/27 Tinned .125 .431 117
6 84/25 Tinned .125 .473 157
4 133/25 Tinned .125 .526 219
2 665/30 Tinned .125 .560 296
1/0 1064/30 Tinned .125 .635 434
3/0 1330/30 Tinned .125 .690 529.5
3/0 1672/30 Tinned .125 .740 646
4/0 2109/30 Tinned .125 .800 795


● EPDM has great dielectric strength, abrasion resistance, low temp flexibility and stripping ability.

SIS
Chemically Cross-linked Polyethylene (XLP)
(90C) (600 Volts) (VW-1) (FT 1)

Wire Gauge (AWG) Conductor Stranding Insulation Thickness Wire Thickness Approximate Lbs.
per 1000ft
14 7/22 Tinned .030 .147 17
14 41/30 Tinned .030 .150 20
12 7/20 Tinned .030 .156 23
12 65/30 Tinned .030 .160 28
10 105/30 Tinned .030 .190 41
8 133/29 Tinned .045 .270 74
6 133/27 Tinned .060 .339 110
4 133/25 Tinned .060 .391 165
2 133/23 Tinned .060 .466 253


● Used for instrument and control wiring of switchboards, annunciator circuits, and industrial control.
● We can stripe and print for your needs.

SR/3212/3213/3214
Braidless Fixture, Apparatus and Motor Lead (600 Volts) (150C)

Wire Gauge (AWG) Conductor Stranding Insulation Thickness Wire Thickness Approximate Lbs.
per 1000ft
18 16/30 Tinned .045 .135 12
16 26/30 Tinned .045 .148 16
14 41/30 Tinned .045 .164 22
12 65/30 Tinned .045 .180 31
10 105/30 Tinned .045 .205 45
8 133/29 Tinned .060 .285 80
6 133/27 Tinned .060 .326 116
4 133/25 Tinned .060 .381 172
2 259/26 Tinned .060 .449 254
1 259/25 Tinned .080 .532 325
1/0 259/24 Tinned .080 .584 402
2/0 259/23 Tinned .080 .625 510
3/0 259/22 Tinned .080 .675 630
4/0 259/21 Tinned .080 .746 773


● Used for leads to motors, transformers, appliance, electric or other electrical circuits where a flexible conductor is required to operate under high temp conditions and where moisture may be present.
● Conductor is flexible stranded.  A silicone compound is applied over the conductor.
● Braidless silicone is more flexible than silicone with a glass braid (SRML).

SRML/3071/3074/3075/3125/3231
Fiberglass Braided Fixture, Apparatus, and Motor Lead Wire (200C) (600 Volts)

Wire Gauge (AWG) Conductor Stranding Insulation Thickness Wire Thickness Approximate Lbs.
per 1000ft
18 7/26 Tinned .030 .111 13
16 7/24 Tinned .030 .122 17
14 7/22 Tinned .030 .142 23
12 19/25 Tinned .030 .165 30
10 19/23 Tinned .045 .217 51
8 54/25 Tinned .060 .301 90
6 84/25 Tinned .060 .323 121
4 133/25 Tinned .060 .406 179
2 259/26 Tinned .060 .474 274
1 259/25 Tinned .080 .557 394
1/0 259/24 Tinned .080 .609 434
2/0 259/23 Tinned .080 .685 536
3/0 259/22 Tinned .080 .735 670
4/0 259/21 Tinned .080 .808 86


● Used for leads to motors, transformers, appliance, electric or other electrical circuits where a flexible conductor is required to operate under high temp conditions and where moisture may be present.
● Conductor is flexible stranded. 
● A silicone compound is applied over the conductor and the wire is then covered with a saturated fray-resistant fiberglass braid.

3239/10475
Braidless Silicone Rubber High Voltage, High Temp Appliance Lead Wire
15 KVDC, 25 KVDC, 40 KDVC (150C) (VW-1)

Wire Gauge (AWG) Conductor Stranding Insulation Thickness Wire Thickness D.C. Voltage Approximate Lbs.
per 1000ft
22 7/30 Tinned .045 .115 15KV 8
22 7/30 Tinned .062 .149 25KV 11
22 7/30 Tinned .097 .219 40KV 21
20 7/28 Tinned .045 .128 15KV 10
20 7/28 Tinned .062 .162 25KV 14
20 7/28 Tinned .097 .232 40KV 25
18 16/30 Tinned .045 .135 15KV 12
18 16/30 Tinned .062 .169 25KV 16
18 16/30 Tinned .097 .239 40KV 28
16 26/30 Tinned .045 .148 15KV 16
16 26/30 Tinned .062 .182 25KV 21
16 26/30 Tinned .097 .252 40KV 33
14 41/30 Tinned .045 .164 15KV 22
14 41/30 Tinned .062 .198 25KV 27
14 41/30 Tinned .097 .268 40KV 40
12 65/30 Tinned .045 .181 15KV 31
12 65/30 Tinned .062 .215 25KV 36
12 65/30 Tinned .097 .285 40KV 50
10 105/30 Tinned .045 .214 15KV 44
10 105/30 Tinned .062 .248 25KV 51
10 105/30 Tinned .097 .318 40KV 67
8 133/29 Tinned .068 .301 25KV 80
6 133/27 Tinned .068 .342 25KV 115
4 133/25 Tinned .068 .401 25KV 166
2 259/26 Tinned .065 .465 25KV 259


● Used in stoves, heaters, furnaces, dryers, motors, therapeutic devices, signs, lighting fixtures, aircraft, submarines and special electronic devices where high temps are incurred.

3257
Braidless Silicone Rubber High Voltage, High Temp Appliance Lead Wire
10 KVAC, 25 KVDC (250C)

Wire Gauge (AWG) Conductor Stranding Insulation Thickness Wire Thickness Approximate Lbs.
per 1000ft
20 7 NPC .078 .194 19
20 7 NPC .112 .262 33
18 16 NPC .078 .200 22
16 26 NPC .078 .2125 27
16 26 NPC .111 .278 41
14 41 NPC .078 .228 34
12 65 NPC .078 .249 44


● Used in high voltage and/or high temp applications such as gas appliance ignitor systems, oil burner ignition circuits, gas fired infra-red heaters and furnaces where protected from repeated flexing, abrasion and physical damage.

TGGS/5256
(TGGS replaces TGGT)
Apparatus Wire (250C) (600 Volts) (UL VW-1 and CSA FT 1)

Wire Gauge (AWG) Conductor Stranding Insulation Thickness Wire Thickness Approximate Lbs.
per 1000ft
24 7/32 NPC .015 .069 3.84
22 7/30 NPC .015 .075 5.06
20 10/30 NPC .015 .081 6.59
18 16/30 NPC .015 .090 8.94
16 26/30 NPC .018 .108 13.5
14 41/30 NPC .018 .123 19.5
12 65/30 NPC .018 .144 28.6
10 105/30 NPC .018 .181 42.8
8 133/29 NPC .018 .213 64.3
6 133/27 NPC .023 .274 103
4 133/25 NPC .023 .327 156
2 133/23 NPC .023 .411 244


● Used for wiring of domestic, commercial and industrial ovens, cooking, curing and drying equipment and similar high temp severe environments including electric heaters, blast furnaces and cement kilns.
● Flexible, stranded nickel-plated copper (NPC) conductor insulated with a composite of polytelrafluoroethylene (PTFE) tape and fiberglass serve jacketed with an overall fiberglass braid saturated and cured with a silicone saturator.  Asbestos and halogen free.
● TGGS gives you the advantage of small diameter due to the reduced wall, yet still gives you the same temperature and voltage of the TGGT it replaces.
● TGGS is superior to TGGT in cutting and stripping.

MGS/5359
(MGS SLIPSTRIP R replaces MGT)
Apparatus Wire (450C) (600 Volts) (UL VW-1 and CSA FT 1)

Wire Gauge (AWG) Conductor Stranding Insulation Thickness Wire Thickness Approximate Lbs.
per 1000ft
22 7/30 NPC .016 .077 4.78
20 10/30 NPC .016 .083 6.27
18 16/30 NPC .016 .092 8.52
16 26/30 NPC .016 .104 12.2
14 41/30 NPC .016 .119 17.9
12 65/30 NPC .016 .140 26.7
10 105/30 NPC .020 .185 41.9
8 133/29 NPC .020 .227 65.8
6 133/27 NPC .020 .268 98.7
4 133/25 NPC .020 .321 151
2 133/23 NPC .025 .415 241


● Used for wiring of domestic and commercial ovens and similar high temp equipment with operating temperatures up to 450C.  Also used for electric heaters, blast furnaces, coke ovens, basic oxygen furnaces and cement kilns.
● Flexible, stranded, 27% nickel-plated conductor (NPC) insulated with a spiral wrapped composite mica tape jacketed with an overall fiberglass braid impregnated with a silicone saturator.  Asbestos and halogen free.
● MGS SLIPSTRIP R gives you the advantage of a smaller diameter due to the reduced wall yet still gives you the same temperature and voltage of the MGT it replaces.
● MGS is superior to MGT in cutting and stripping.