electronic wire

Telephone Silver Satin
Polyvinylchloride (PVC) 60C 150V AWM 20251

Wire Gauge (AWG) No. of Conductors Conductor Colors Conductor
Stranding
Insulation
Thickness
Wire
Thickness
Approximate Lbs.
per 1000ft
26 4 black, red, green, yellow 7/.16 mm  7/34 .009"  .23mm .098 x .197  2.5 x 5.0 12
26 6 white, black, red, green, yellow, blue 7/.16 mm  7/34 .009"  .23mm .098 x .276  2.5 x 7.0 18
26 8 blue, orange, black, red, green, yellow, brown, gray 7/.16 mm  7/34 .009"  .23mm .098 x .347  2.5 x 8.8 23

Coaxial, Security, Video, Plenum, and Non-Plenum
RG6, RG8, RG11, RG58, RG59, RG62, RG71, RG122, RG142, RG174, RG178, RG179, RG180, RG187, RG188, RG196, RG212, RG213, RG214, RG216, RG217, RG223, RG303, RG316, RG401, RG402, RG405.  Other types available.
Voice, Data, and Premise Wire
Overall Shield/Multiple Conductor
UL Type CMR, CL3R, 75C

Wire Gauge (AWG) No. of Conductors Conductor Stranding Insulation Thickness Wire Thickness Approximate Lbs.
per 1000ft
22 2 7BC .015 .13 12
22 3 7BC .015 .14 16
22 4 7BC .015 .15 20
22 6 7BC .015 .17 26
22 8 7BC .015 .20 31
22 12 7BC .015 .23 42
20 2 7BC .015 .15 17
20 3 7BC .015 .15 21
20 4 7BC .015 .17 25
18 2 7BC .015 .16 21
18 3 7BC .015 .17 28
18 4 7BC .015 .19 35
18 6 7BC .015 .23 50
18 8 7BC .015 .25 63
18 12 7BC .015 .30 90
16 2 19BC .015 .19 29
16 3 19BC .015 .20 39
16 4 19BC .015 .22 50
14 2 19BC .015 .25 46
14 3 19BC .015 .25 61
14 4 19BC .015 .27 79


● Used in remote control signaling, power-limited circuits, security, intercom, public address, sound, and audio systems.
● Offers protection from electrostatic interference.
● Conductors are soft bare annealed copper per ASTM B-3.
● Insulation is semi-rigid PVC.
● Jacket is gray PVC with a ripcord applied longitudinally under the jacket.
Additional Standards:  22AWG-16AWG: UL standard 13, NEC Article 725 Type CL3R and Ul Standard 444, NEC Article 800 Type CMR;  -  UL stadard 13, NEC Article 725 Type CL3R.
Voice, Data, and Premise Wire
Non-shielded/Multiple Conductor
UL Type CMR, CL3R, 75C

Wire Gauge (AWG) No. of Conductors Conductor Stranding Insulation Thickness Wire Thickness Approximate Lbs.
per 1000ft
22 2 7BC .008 .12 9
22 3 7BC .008 .14 13
22 4 7BC .008 .16 17
22 6 7BC .008 .17 22
22 8 7BC .008 .18 27
22 12 7BC .008 .22 42
20 2 7BC .008 .13 11
20 3 7BC .008 .13 18
20 4 7BC .008 .14 22
18 2 7BC .009 .16 18
18 3 7BC .009 .17 24
18 4 7BC .009 .18 31
18 6 7BC .009 .23 46
18 8 7BC .009 .25 59
18 12 7BC .009 .29 86
16 2 19BC .009 .18 26
16 3 19BC .009 .19 35
16 4 19BC .009 .21 47
14 2 19BC .013 .22 41
14 3 19BC .013 .24 55
14 4 19BC .013 .26 72
12 2 19BC .013 .26 57


● Used in remote control signaling, power-limited circuits, security, intercom, public address, sound, and audio systems.
● Offers protection from electrostatic interference.
● Conductors are soft bare annealed copper per ASTM B-3.
● Insulation is semi-rigid PVC.
● Jacket is gray PVC with a ripcord applied longitudinally under the jacket.
● Additional Standards:  22AWG-16AWG: UL standard 13, NEC Article 725 Type CL3R and Ul Standard 444, NEC Article 800 Type CMR;  -  UL stadard 13, NEC Article 725 Type CL3R.